Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Int. j. cardiovasc. sci. (Impr.) ; 36: e20220007, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1430496

RESUMO

Abstract Background: Monocytes are essential components in inflammatory signaling, and their recruitment is crucial in the signaling pathway, which directs and determines cell adhesion to the activated endothelium. A better understanding of the correlation between monocyte subsets and inflammatory signaling in patients with atherosclerotic disease in acute coronary syndrome (ACS) is essential for the development of more effective therapies for the prevention and treatment of cardiovascular diseases. Objective: To analyze differences between biomarkers and monocyte activation in the setting of ischemic heart disease. Methods: This was a case-control study comparing biomarkers and monocyte subsets between patients with ACS with and without ST-segment elevation and individuals without coronary stenosis. The nonparametric Kruskal-Wallis test was used to assess differences between groups, and Dunn's post hoc test was used to identify which groups were different. Cuzick's test for ordered group trends was used to assess falling or rising trends. Participants were classified into 3 groups: control (0); non-ST-elevation myocardial infarction (NSTEMI) (1); ST-elevation myocardial infarction (STEMI) D1 (2). Results: Forty-seven patients with ACS and 19 controls with no obstructive lesions on coronary angiography were recruited. Monocyte profile assessment was statistically different regarding time of symptom onset and the presence or absence of atherosclerotic disease (Kruskal-Wallis, p = 0.0009). Dunn's post hoc test showed a significant difference between the control group and the STEMI D1 (p = 0.0014), STEMI D3 (p = 0.0036), and STEMI D7 (p = 0.0195) groups, corresponding to a 2-fold increase in classical (p = 0.0022) and nonclassical (p = 0.0031) monocytes compared with controls. For classical monocytes, there was a difference between the control group and all STEMI groups and between the NSTEMI group and the STEMI D1, D3, and D7 groups. For nonclassical monocytes, there was a difference between the control group and the STEMI D7 group (p = 0.0056) and between the NSTEMI group and the STEMI D7 group (p = 0.0166). Conclusion: This study found that there was an increase in total and classical monocyte mobilization at the time of acute myocardial infarction in patients with ACS.

2.
J. Transcatheter Interv ; 31: eA20230009., 2023. ilus; tab
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1511103

RESUMO

Introdução: As extensões de cateter-guia fornecem maior suporte em intervenções coronárias percutâneas complexas. O ExpressmanTM é uma nova extensão de cateter-guia, e nosso objetivo foi avaliar o impacto de seu uso no sucesso do procedimento e nas complicações ocorridas em um centro de referência de alto volume. Métodos: Analisamos os dados de todos os procedimentos consecutivos em que foi usada uma extensão de cateter-guia ExpressmanTM. A decisão de usar uma extensão de cateter-guia ficou a critério do operador. O sucesso do dispositivo foi definido como o posicionamento bem-sucedido da extensão de cateter-guia dentro do vaso coronário, e o sucesso do procedimento foi definido como <20% de estenose residual e fluxo TIMI 3, sem perda significativa de ramos laterais. Eventos adversos cardíacos e cerebrovasculares maiores foram definidos como a combinação morte por todas as causas, infarto do miocárdio, revascularização do vaso-alvo e acidente vascular cerebral. Resultados: Foram incluídos 34 procedimentos entre abril de 2022 e janeiro de 2023. A maioria dos pacientes era do sexo masculino (59%), e a média de idade foi 66,5 anos. O uso da extensão de cateter-guia não foi planejado antes do procedimento em 17 procedimentos (50%). Os motivos mais comuns para o uso da extensão de cateter-guia foram angulação ou tortuosidade do vaso-alvo e posição desfavorável do óstio coronário. O sucesso do dispositivo foi obtido em 88% e o da revascularização, em 91%. Houve três oclusões de ramo lateral. Durante o acompanhamento clínico intra-hospitalar, não ocorreram sangramento e nem eventos adversos cardíacos e cerebrovasculares maiores. Conclusão: O sucesso do dispositivo e do procedimento foi alto, e a taxa de complicações foi baixa. O uso da extensão de cateter-guia como técnica de resgate em anatomias complexas permitiu o sucesso do procedimento na maioria dos pacientes que, de outro modo, não poderiam ser tratados.


Background: Guide catheter extensions provide increased support in complex percutaneous coronary interventions. The ExpressmanTM is a novel guide catheter extension and the objective was to assess the impact of its use on procedural success and complications in a high-volume reference center. Methods: We analyzed data from all consecutive procedures in which the ExpressmanTM guide catheter extension was used. The decision to use a guide catheter extension was at operator's discretion. Device success was defined as the successful positioning of the guide catheter extension in the coronary vessel and procedural success was defined as <20% residual stenosis and TIMI 3 flow, with no loss of significant side branches. Major adverse cardiac and cerebrovascular events were defined as the composite of all-cause death, myocardial infarction, target vessel revascularization and stroke. Results: From April 2022 to January 2023, 34 procedures were included. The majority of the patients were male (59%) and the mean age was 66.5 years. Guide catheter extension use was not planned pre-procedure in 17 procedures (50%). The most common reasons for guide catheter extension use were target vessel angulation or tortuosity and unfavorable coronary ostium position. Device success was obtained in 88% and revascularization success in 91%. There were three side branch occlusions. During in-hospital clinical follow-up, no major adverse cardiac and cerebrovascular events or major bleeding occurred. Conclusion: The device success and procedural success were high and the rate of complications was low. Guide catheter extension use as bailout technique in complex anatomies allowed procedural success in the vast majority of otherwise untreatable patients.

3.
J. Transcatheter Interv ; 30: eA20220004, 20220101. ilus
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1399114

RESUMO

Apresentamos o caso debutante na América Latina de reparos transcateteres edge- to-edge nas valvas mitral e tricúspide em um único procedimento em paciente de alto risco para cirurgia. A paciente evoluía com insuficiência cardíaca e limitações em suas atividades diárias quando foi submetida ao procedimento, no qual foram realizados os reparos transcateteres das valvas mitral e tricúspide. Aos 6 meses de evolução, estava assintomática e realizando suas atividades diárias. Debatemos as recomendações mais atualizadas sobre a terapia transcateter para coexistência dessas doenças valvares, assim como expomos as lacunas no conhecimento.


We present the first case in Latin America of transcatheter edge-to-edge mitral and tricuspid valve repair in a single procedure, in a patient at high risk for surgery. The patient progressed to heart failure and limitation in her daily living activities when she was submitted to transcatheter mitral and tricuspid valve repair. Six months later, she was asymptomatic and performing her daily living activities. We discuss the most updated recommendations for transcatheter repair when both valvar conditions coexist, and show the knowledge gaps.

4.
Rev. bras. cardiol. invasiva ; 19(1): 28-33, mar. 2011.
Artigo em Português | LILACS | ID: lil-591715

RESUMO

Introdução: A estenose aórtica é uma afecção prevalente e com altas taxas de morbidade e mortalidade, sendo atroca valvular cirúrgica a abordagem clássica. Indivíduos idosos e com outras comorbidades apresentam elevadorisco operatório. O implante valvular aórtico percutâneo surge como alternativa à cirurgia padrão. O objetivo deste estudo é apresentar o seguimento de dois anos dos primeiros casos realizados no Sul do Brasil com essa abordagem inédita. Métodos: Série de casos com descrição da técnica e resultados imediatos e a médio prazo do implante do dispositivo CoreValveTM (Medtronic Inc., Minneapolis, EstadosUnidos), que consiste de uma bioprótese de pericárdio porcino montada em stent auto expansível de nitinol, introduzido pela via arterial. Resultados: Foram submetidos ao implante desse dispositivo quatro pacientes do sexo feminino, com idade variando entre 81 anos e 90 anos e EuroSCORE logístico de 20% a 36%. Observou-se significativa queda do gradiente ventrículo esquerdo-aorta, assim como ausência de complicações cardiovasculares maiores, embora duas pacientes tenham necessitado de implante de marca-passo definitivo por distúrbio de condução atrioventricular.No seguimento de dois anos observou-se melhora da classe funcional e manutenção dos gradientes e das áreas valvares aórticas alcançadas no final do procedimentoe diminuição progressiva da massa ventricular esquerda. Conclusões: Esta experiência inicial com implante valvularaórtico percutâneo tem se mostrando segura e efetiva em análise a médio prazo. Estudos com seguimento a longoprazo são necessários para definir o exato papel e precisas indicações dessa nova e promissora técnica.


Background: Aortic stenosis is a prevalent disease with high morbidity and mortality, whose classical approach is surgical valve replacement. Elderly patients and those with other comorbidities present high surgical risk. Transcatheter aortic valve implantation is an effective alternative to standardsurgery. The objective of this study is to report the 2-year follow-up of the first cases performed in Southern Brazil.Methods: Series of cases describing the technique, immediate and medium term results of the CoreValveTM (Medtronic Inc., Minneapolis, USA) device implantation, a porcine pericardialbioprosthesis mounted on a self expanding nitinol stent, delivered via transarterial access. Results: Four female patients, with ages ranging from 81 to 90 years and a logistic EuroSCORE ranging from 20% to 36% were successfully submitted to the implantation of this device. A significantreduction in the left ventricle-aortic gradient, and no major cardiovascular complications were observed, although2 patients required the implantation of a permanent pacemaker due to complete atrioventricular block. Improvementof functional class and maintenance of gradients and aortic valve areas obtained at the end of the procedure,as well as a progressive decrease of left ventricular mass were observed in the 2 year follow-up. Conclusions: Thisearly experience with the CoreValveTM transcatheter aortic valve implantation has proved to be safe and effective in the medium term outcome. Long-term follow-up studies are required to define the exact role and adequate indicationsfor this new and promising technology.


Assuntos
Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Aspirina/administração & dosagem , Ecocardiografia
5.
Rev. bras. cardiol. invasiva ; 19(1): 65-71, mar. 2011.
Artigo em Português | LILACS | ID: lil-591721

RESUMO

Introdução: Estudos que analisaram o estado de saúde não avaliaram diferenças entre pacientes com angina instável e infarto agudo do miocárdio com (IAMCST) e sem (IAMSST) elevação do segmento ST. Este estudo teve como objetivo comparar índices do estado de saúde, de acordo com o Questionário de Angina de Seattle (QAS), em pacientes com síndrome coronária aguda (SCA). Métodos: O QAS foi aplicado na admissão hospitalar e aos seis meses de acompanhamento em 391 pacientes com SCA. Foram analisados três domínios: limitação física (D1), frequência da angina (D3) e qualidade de vida (D5). Índices maiores em D1, D3 e D5 significam menor limitação física, menor frequência da angina e melhor qualidade de vida, respectivamente. Resultados: Na internação hospitalar, pacientes com angina instável apresentaram piores índices de frequência da angina e de qualidade de vida que os portadores de IAMSST, e piores índices de atividade física, frequência da angina e qualidade de vida que aqueles com IAMCST. Aos seis meses de seguimento, os pacientes com angina instável ainda apresentaram piores índices de atividade física, frequência da angina e qualidade de vida que os portadores de IAMCST, mas sem diferença significativa em relação aos pacientes com IAMSST. Pacientes com angina instável foram aqueles que apresentaram maior ganho em todos os domínios do QAS. Conclusões: No espectro da SCA, os pacientes com angina instável demonstraram pior estado de saúde, tanto na internação hospitalar como aos seis meses de acompanhamento, mas, por outro lado, foram os que apresentaram o maior ganho em cada um dos domínios avaliados pelo QAS.


Background: Studies assessing health status have not addressed differences among patients with unstable angina, non- ST elevation myocardial infarction (NSTEMI) and ST-elevation myocardial infarction (STEMI). This study was aimed at comparing health status scores according to the Seattle Angina Questionnaire (SAQ) in patients with acute coronary syndromes (ACS). Methods: SAQ was applied at hospitaladmission and at 6-month follow-up in 391 patients with ACS. Three domains were analyzed: physical limitation (D1),anginal frequency (D3) and disease perception (D5). Higher D1, D3 and D5 scores indicated less physical limitation,lower frequency of angina and better quality of life, respectively. Results: At hospital admission, patients with unstable angina presented significantly lower scores of anginal frequencyand disease perception than those with NSTEMI, and significantly lower scores of physical activity, anginal frequency and disease perception than those with STEMI. At the 6-month follow-up, patients with unstable angina still presented lower scores of physical activity, anginal frequency and disease perception than those with STEMI,but there were no significant differences when compared to those with NSTEMI. The SAQ domains increased to a greater extent in patients with unstable angina. Conclusions:Patients with unstable angina had worse health status at hospital admission and at the 6-month follow-up but, on the other hand, showed the largest improvements for each one of the SAQ domains analyzed.


Assuntos
Humanos , Masculino , Feminino , Adulto , Nível de Saúde , Síndrome Coronariana Aguda , Hospitalização , Qualidade de Vida
6.
Rev. bras. cardiol. invasiva ; 19(1): 84-89, mar. 2011.
Artigo em Português | LILACS | ID: lil-591724

RESUMO

Introdução: Procedimentos cardiológicos invasivos expõem pacientes e médicos aos riscos da radiação ionizante. É objetivo deste estudo determinar os padrões e preditores de superexposição radiológica durante procedimentos cardiológicos. Métodos: Estudo de coorte prospectivo que avaliou pacientes submetidos a procedimentos cardiológicos invasivos entre agosto de 2010 e janeiro de 2011 em equipamento com detectores planos. Características clínicas, angiográficas e de exposição à radiação foram registradas em banco de dados específico. Os padrões de exposição à radiação foram determinados em pacientes submetidos a cateterismo cardíaco, a intervenção coronária percutânea eletiva (ICP-e) e a intervenção coronária percutânea ad hoc (ICP-AH). Preditores independentes de exposição à radiação aumentada foram identificados por análise de regressão logística múltipla. Resultados: A população incluiu 670 pacientes, sendo 419 submetidos a cateterismo cardíaco, 137 a ICP-e e 114 a ICP-AH. A dose média de radiação recebida pelos pacientes foi de 561,8 ± 368,1 mGy (cateterismo cardíaco), 1.125,5 ± 1.120 mGy (ICP-e) e 1.293,4 ± 726,3 mGy (ICP-AH). O produto dose-área foi de 37.725,8 ± 27.027,5 mGy.cm2 (cateterismo cardíaco), 61.643,1 ± 64.383,7 mGy.cm2 (ICP-e) e 77.973,4 ± 49.959,3 mGy.cm2 (ICP-AH). Os preditores de exposição radiológica aumentada foram peso [razão de chance (RC) 1,03, intervalo de confiança (IC) 1,01-1,05; P = 0,003], ICP-e (RC 11,9, IC 4,3-33,2; P < 0,001) e ICP-AH (RC 15,5, IC 5,4-43,9; P < 0,001). Conclusões: Os padrões de exposição radiológica durante procedimentos cardiológicos invasivos usando detectores planos estão abaixo do limite estabelecido pela Agência Internacional de Energia Atômica. Peso e procedimentos de ICP-e e ICP-AH são preditores de superexposição radiológica.


Background: Invasive cardiologic procedures expose patients and physicians to the risks of ionizing radiation. The aim of this study is to determine patterns and predictors ofradiation overexposure during cardiologic procedures. Methods:Prospective cohort study to investigate patients undergoing invasive cardiologic procedures between August 2010and January 2011 in flat detector fluoroscopy systems. Clinical,angiographic and radiation exposure characteristics were recorded in a dedicated database. Radiation exposurepatterns were determined in patients undergoing coronary angiography, elective (e-PCI) and ad hoc (AH-PCI) percutaneous coronary intervention. Independent predictors of increasedradiation exposure were identified by multiple logistic regression analysis. Results: The study population included 670 patients, 419 undergoing coronary angiography, 137 e-PCI and 114 AH-PCI. The mean radiation dose received by the patients was 561.8 ± 368.1 mGy (coronary angiography), 1,125.5 ± 1,120 mGy (e-PCI) and 1,293.4 ± 726.3 mGy (AH-PCI). Dose-area product was 37,725.8 ±27,027.5 mGy.cm² (coronary angiography), 61,643.1 ± 64,383.7 mGy.cm² (e-PCI) and 77,973.4 ± 49,959.3 mGy.cm² (AH-PCI). Predictors of increased radiation exposure were body weight [odds ratio (OR) 1.03, confidence interval (CI)1.01-1.05; P = 0.003), e-PCI (OR 11.9, CI 4.3-33.2; P < 0.001) and AH-PCI (OR 15.5, IC 5.4-43.9; P < 0.001). Conclusions: Radiation exposure patterns during invasive cardiologicprocedures using flat detector fluoroscopy systems are below the threshold established by the International Atomic Energy Agency...


Assuntos
Humanos , Masculino , Feminino , Adulto , Cateterismo Cardíaco , Exposição à Radiação , Procedimentos Cirúrgicos Cardíacos , Radiação Ionizante
7.
Rev. bras. cardiol. invasiva ; 17(1): 39-45, jan.-mar. 2009. tab
Artigo em Português | LILACS | ID: lil-521582

RESUMO

Fundamentos: A presença de estenose residual (ER) negativa após o implante de stents coronarianos em pacientes com infarto do miocárdio está associada a piores desfechos clínicos. A influência da ER no prognóstico de pacientes com síndrome coronariana aguda sem supradesnivelamento do segmento ST não foi bem estudada. Método: Pacientes com síndrome coronariana aguda sem supradesnivelamento do segmento ST tratados com implante de stents coronarianos foram incluídos, e a ER e o fluxo coronariano foram avaliados imediatamente após o procedimento. Pacientes com ER < 0% foram comparados a um grupo controle com ER 0-30% quanto à ocorrência de eventos cardíacos adversos maiores (ECAM) em um ano. Resultados: As características clínicas foram semelhantes em ambos os grupos. A ER média foi de -10,3 ± 6,4% no grupo ER < 0% (n = 94) e de 2,1 ± 5,2% nos controles (n = 298) (P < 0,001). Pacientes com ER < 0% tinham vasos menores (P < 0,001) e apresentaram maior escore de agressividade (P < 0,001), que foram preditores independentes de ER negativa, comparativamente aos pacientes com ER 0-30%. Os índices de sucesso clínico do procedimento (100% vs. 98,7%), fluxo coronariano TIMI 3 (100% vs. 99,3%), ECAM intra-hospitalares (0% vs. 0,6%) e trombose subaguda (1,1% vs. 0,3%) não foram estatisticamente diferentes nos pacientes com ER < 0% e nos controles. Os índices de revascularização do vaso-alvo (8,9% vs. 7,9%) e de ECAM em um ano (10% vs. 10%) também foram semelhantes nos pacientes com ER < 0% e nos controles. Conclusões: A ocorrência de ER negativa após o implante de stents coronarianos em pacientes com síndrome coronariana aguda sem supradesnivelamento do segmento ST foi associada a vasos menores e a estratégias de implante mais agressivas, mas não à piora do fluxo coronariano ou a índices mais elevados de ECAM.


Background: Negative residual stenosis (RS) after coronary stenting is associated with worse antegrade flow and increased mortality in patients with acute myocardial infarction. Its influence on outcomes of patients with nonST elevation acute coronary syndromes is unknown. Methods: Patients with acute coronary syndrome with nonST elevation treated with coronary stenting were included and RS and coronary flow were assessed immediately after the procedure. Patients with RS < 0% were compared to a control group with RS 0-30% for the occurrence of one-year MACE. Results: Baseline clinical characteristics were similar in both groups. Mean residual stenosis was -10.3 ± 6.4% in the < 0% RS group (n = 94) and 2.1 ± 5.2% in controls (n = 298) (P < 0.001). Patients with RS < 0% had smaller vessels (P < 0.001) and were treated with a higher aggressiveness score (P < 0.001), which were independent predictors of the occurrence of negative RS. Clinical procedural success rates (100% vs. 98.7%) and coronary TIMI 3 flow rates (100% vs. 99.3%) were similar in both groups. In-hospital MACE (0% vs. 0.6%) and subacute thrombosis rates (1.1% vs. 0.3%) were not statistically different. One-year target vessel revascularization rates (8.9% vs. 7.9%) and one-year MACE rates (10% vs. 10%) were also similar. Conclusions: Negative residual stenosis after coronary stenting in patients with non-ST elevation acute coronary syndrome was associated with smaller vessels and more aggressive implantation strategies, but not with worse coronary flow or higher MACE rates.


Assuntos
Humanos , Stents , Angina Instável/terapia , Doença das Coronárias/diagnóstico , Angiografia Cerebral , Reestenose Coronária
8.
Rev. bras. cardiol. invasiva ; 16(4): 495-498, out.-dez. 2008. ilus
Artigo em Português | LILACS | ID: lil-508796

RESUMO

Apresenta-se neste relato o tratamento bem-sucedido de dois pacientes com lesões coronárias complexas, calcificadas, sendo uma delas uma oclusão total crônica, na qual foi utilizado um novo dispositivo para facilitar o procedimento percutâneo.


We describe two complex cases of calcified lesions, one of which a total chronic occlusion, that were successfully treated with a new device that facilitates the percutaneous procedure.


Assuntos
Humanos , Masculino , Idoso , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão , Calcinose/complicações , Estenose Coronária/complicações , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Cateterismo/instrumentação
9.
Rev. bras. cardiol. invasiva ; 16(4): 445-449, out.-dez. 2008. tab, graf
Artigo em Português | LILACS | ID: lil-508789

RESUMO

Fundamentos: As doenças cardiovasculares são um importante problema de saúde pública, e as respostas adaptativas e protetoras da vasculatura contra o estresse oxidativo são importantes na prevenção da aterosclerose. A bilirrubina tem sido considerada um antioxidante, com capacidade de remover espécies reativas de oxigênio. Estudos têm demonstrado que a concentração de bilirrubina sérica aumentada promove proteção contra aterosclerose. Objetivo: Avaliar a possível existência de relação entre a carga aterosclerótica de pacientes com doença arterial coronariana e a concentração de bilirrubina. Método: Estudo transversal composto por 81 pacientes com diagnóstico angiográfico estabelecido de doença arterial coronariana, submetidos a revascularização miocárdica. Foram avaliados os fatores de risco clássicos e a dosagem de bilirrubina. Foram utilizados os testes do qui-quadrado, teste t de Student ou Mann-Whitney, sendo considerado p < 0,05 estatisticamente significativo. Resultados: A amostra foi composta predominantemente por homens, com média de idade de 59,32 ± 9,28 anos no grupo com lesão mínima/moderada e 61,79 ± 7,55 anos no grupo com lesão grave. A mediana da bilirrubina total no grupo com lesão mínima/moderada foi de 0,34 mg/dL, enquanto no grupo com lesão grave foi de 0,43 mg/dL, diferente do esperado. A concentração de bilirrubina total foi maior no grupo com carga aterosclerótica grave que no grupo com carga mínima/moderada, embora sem significância estatística (p = 0,241). Conclusão: Níveis séricos de bilirrubina não se mostraram úteis na detecção ou predição da gravidade da lesão aterosclerótica dos pacientes com doença arterial coronariana.


Background: Cardiovascular diseases are an important public health problem. Adaptive and protective responses of the vascular system against oxidative stress are important in the prevention of atherosclerosis. Bilirubin has been considered an antioxidant, with the capacity to remove reactive species of oxygen. Previous studies have demonstrated that increased serum bilirubin concentrations promote protection against atherosclerosis. Purpose: To evaluate the relationship between the atherosclerotic burden and the bilirubin concentration of patients with coronary artery disease. Method: Transversal study composed of 81 patients with established angiographic diagnosis of coronary artery disease, submitted to myocardial revascularization. Classical risk factors and bilirubin levels were assessed. The chisquare, the t Student test or the Mann-Whitney test were used with p value significant at < 0.05. Results: The sample was composed predominantly of men, with a mean age of 59.32 ± 9.28 years in the minimum/moderate atherosclerotic burden group and 61.79 ± 7.55 years in the severe burden group. The median of total bilirubin in the minimum/moderate atherosclerosis burden group was 0.34 mg/dL and 0.43 mg/dL in the severe burden group. Differently than expected, the concentration of total bilirubin was higher in the group with severe atherosclerotic burden than in the group with minimum/moderate burden, although without statistical significance (p = 0.241). Conclusion: Serum bilirubin levels were not useful in the detection or prediction of the severity of atherosclerotic lesions in patients with coronary artery disease.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Aterosclerose/prevenção & controle , Bilirrubina/análise , Fatores de Risco , Revascularização Miocárdica
10.
Rev. bras. cardiol. invasiva ; 16(4): 398-405, out.-dez. 2008. tab, ilus, graf
Artigo em Português | LILACS | ID: lil-508782

RESUMO

Introdução: A estenose aórtica grave é uma doença prevalente e de alta morbidade e mortalidade, sendo a troca valvar por meio de cirurgia cardíaca a abordagem clássica. Todavia, indivíduos idosos e com outras co-morbidades apresentam elevado risco operatório. O implante valvular aórtico percutâneo pela via retrógrada desponta como uma alternativa exeqüível e efetiva. São descritos os primeiros casos realizados no Sul do Brasil com essa abordagem inédita. Método: Série de três casos com descrição da técnica e resultados imediatos do implante do dispositivo CoreValve, que consiste de uma bioprótese com três folhetos de pericárdio porcino montados e suturados e um stent auto-expansível de nitinol, introduzido pela via arterial femoral ou ilíaca. Resultados: Três pacientes do sexo feminino com 81, 85 e 90 anos de idade e EuroSCORE logístico variando de 20% a 36% foram submetidas ao implante desse dispositivo com sucesso. Houve significativa queda dos gradientes entre o ventrículo esquerdo e a aorta e ausência de complicações cardiovasculares maiores, embora duas pacientes tenham necessitado de implante de marca-passo definitivo por distúrbio de condução atrioventricular. Todas as pacientes receberam alta assintomáticas e seguem em avaliação clínica. Conclusão: A experiência inicial do Sul do Brasil com implante valvular aórtico percutâneo se mostrou segura e efetiva em análise a curto prazo. Estudos adicionais e seguimento mais prolongado ainda são necessários para definir o exato papel e as precisas indicações dessa nova e promissora técnica.


Background: Severe aortic stenosis is a prevalent disease with high rates of morbidity and mortality. The classic approach to its treatment is through heart valve replacement surgery. However, elderly patients and others with different comorbidities present high surgical risk. The percutaneous aortic valve implantation through a retrograde approach has emerged as a feasible and effective alternative treatment for this issue. We describe the first series of cases treated with this new approach in the South of Brazil. Methods: Series of three cases describing the procedure and immediate results of CoreValve device implantation. This device consists in a bioprosthesis with three porcine leafs mounted and sutured in a self-expandable nitinol stent introduced through the femoral or iliac artery. Results: Three female patients aged 81, 85 and 90 years with a logistic EuroSCORE varying from 20% to 36% were successfully submitted to the implantation of this device. A significant reduction in all gradients between the left ventricle and the aorta was observed. There were no reports of major cardiovascular complications, although in two patients the implantation of a permanent pacemaker was needed due to an atrioventricular conduction disorder. All patients were discharged asymptomatic and were kept in a long-term clinical followup evaluation program. Conclusion: The initial short-term experience with the percutaneous retrograde aortic valve implantation in the south of Brazil was feasible and safe. Additional studies and long-term follow-up are still necessary in order to define the precise role and adequate indications for this new and very promising technique.


Assuntos
Humanos , Feminino , Idoso , Próteses e Implantes , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Valvas Cardíacas/cirurgia , Fatores de Risco , Próteses Valvulares Cardíacas
12.
Rev. bras. cardiol. invasiva ; 15(1): 44-51, jan.-mar. 2007. tab, ilus
Artigo em Português | LILACS | ID: lil-452028

RESUMO

Introdução: As complicações relacionadas ao cateterismo cardíaco são os principais limitantes desta técnica, e podem variar desde eventos adversos leves e transitórios até eventos graves, como infarto do miocárdio ou morte. Objetivo: Avaliar a incidência de complicações imediatas do cateterismo cardíaco diagnóstico em adultos, conforme um modelo de categorização das complicações em tipo e gravidade. Método: Estudo de coorte prospectivo em um centro de referência. As características dos pacientes foram registradas, e estes foram acompanhados até a alta hospitalar. As complicações foram categorizadas em nove modalidades: alérgica, isquêmica, vascular, arrítmica, vaso-vagal, pirogênica, neurológica, embólica e congestivas, e estratificadas em leves (intercorrências), moderadas (resolvidas em até 24 horas) ou graves (necessitou internação ou intervenção). Os fatores preditivos de complicações foram identificados por análise multivariada. Resultados: Foram incluídos 1916 indivíduos, sendo 59,4% do sexo masculino e com média de idade de 58,3±11,1 anos. Complicações ocorreram em 175 pacientes (190 eventos), sendo que 62,5% foram intercorrências leves, 24% moderadas e 13,5% graves. Foi registrado apenas um óbito (0,05% dos indivíduos). As complicações vasculares foram as mais incidentes (35,6%), seguidas das vagais (18,3%), isquêmicas (15,4%) e alérgicas (14,4%). Os fatores de risco para complicações pela análise multivariada foram uso de anticoagulante (3,59; 1,67-7,74; p=0,006) e duração prolongada do exame (1,03; 1,02-1,04; p<0,001). Conclusão: As complicações relacionadas ao cateterismo cardíaco são geralmente intercorrências sem gravidade, sendo que as complicações vasculares, reações vagais e isquêmicas foram as mais freqüentes. O uso de anticoagulantes e o tempo de exame prolongado foram os principais fatores preditivos de complicações.


Background: The major limitations of cardiac catheterization are the occurrence of complications related to its invasive nature. Complications can vary from mild and transitory reactions to severe adverse events like myocardial infarction or death. Objective: To assess the incidence, type and severity of complications related to cardiac catheterization in adults using a comprehensive system previously described. Methods: We conducted a prospective cohort study in a tertiary reference center, and patient characteristics and in-hospital outcomes were registered in a dedicated database. Complications were categorized in nine types: allergic, ischemic, vascular, arrythmic, vagal, pyrogenic, neurological, embolic and congestive, and stratified in mild, moderate (resolved in 24 hours) or severe (needed hospitalization or another intervention). The predictive factors of complications were assessed by multivariate analysis. Results: We included 1916 individuals, 59% male and with a mean age of 58±11 years. Complications occurred in 175 patients (190 events), and 63% were mild, 24% moderate e 13% severe. There was one (0.05%) death in the entire cohort. Vascular complications were the most common type (36%), followed by vagal (18%), ischemic (15%) and allergic (14%). Risk factors for complications by multivariate analysis were anticoagulant use (OR=3.59; CI=1.67-7.74; p=0.006) and prolonged examination time (OR=1.03; CI=1.02-1.04; p<0.001). Conclusions: In-hospital complications after cardiac catheterization are generally mild, and the events more commonly presented were vascular, vagal or ischemic. Anticoagulant use and prolonged examination time were independent predictors of complications.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Angiografia/efeitos adversos , Cateterismo Cardíaco , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco , Fatores de Risco
13.
J. pneumol ; 20(1): 24-8, mar. 1994. tab
Artigo em Português | LILACS | ID: lil-175772

RESUMO

Objetivou-se, com o presente estudo, avaliar a contribuiçäo da fibroboncoscopia no diagnóstico do carcinoma brônquico. Foram analisados, retrospectivamente, 190 pacientes com esta entidade patológica, divididos em dois grupos, conforme a presença de lesäo visível à endoscopia (n=114) ou a sua ausência (n=76). O estudo anatomopatológico da biopsia brônquica ou transbrônquica e/ou a citopatologia do lavabo ou escovado brônquico, obtidos pelo fibrobroncoscopia, demonstraram uma sensibilidade de 72,1 por cento na confirmaçäo diagnóstica de neoplasia pulmonar. Quando a lesäo era visível à inspeçäo endoscópica, a sensibilidade do método atingiu porcentual de 92 por cento, sendo a biópsia positiva em 76,7 por cento e a citologia, em 53,3 por cento. Quando a árvore brônquica näo apresentava alteraçöes o rendimento desta é sensivelmente menor (42,4 por cento), sendo que a citopatologia mostrou porcentual de sensibilidade de 39,1 por cento e a biópsia, de 18,2 por cento, consideravelmente menores que para lesöes visíveis


Assuntos
Humanos , Feminino , Masculino , Brônquios/citologia , Brônquios/patologia , Broncoscopia , Carcinoma Broncogênico/diagnóstico , Neoplasias Pulmonares/patologia , Biópsia , Brasil , Carcinoma Broncogênico/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA